Page 234 - Bluebook Sereco english
P. 234
www.sereco.it
14CpIg14CpIg 05102015 1503 Pagia 220
Compact Plants
AQUA LS mobile drinking water unit for water
with low salinity
he drinking water system for superfi- The unit is capable of removing from Main components of the process
Tcial fresh water or well water AQUA water various contaminations due to
LS type is a containerised compact unit suspended solids, organic and chemical
able to solve both permanent drinking micro pollutants, bacteria and make it • MOTOR PUMP FOR RAW
WATER DRAWING;
water shortage problems and to provide suitable for human consumption, accor-
for temporary needs due to natural dis- ding to the drinking water parameters • CHEMICAL CONDITIONING;
asters or emergencies. guidelines set by WHO. • LAMELLA SETTLING;
DESCRIPTION AND APPLICATION PROCESS • INTERMEDIATE SETTLING AND
DISINFECTIONS;
he unit is composed mainly of one or solids being removed in the treatment • INTERMEDIATE LIFTING;
Tmore 20' and/or 40'containerised previously described, is stored in an • FILTRATION WITH SAND AND
modules that will be, time by time, tro- intermediate disinfections and storing ACTIVATED CARBON;
picalized, insulated and conditioned tank. The storing is able to allow a sui- • BACTERIA REMOVAL BY UV.
according to the environment and the table contact time for disinfections and
working condition. enough storing volume for filters was-
Time by time the unit could be equipped hing. Disinfected water, by motor pump,
with an autonomous power generator is pumped in one or more sand and/or
unit, automatization and computerized activated carbon filters, for removing on
control of the process. the sand bed residual suspended solids
The turbid water, drawn from the river and on the activated carbon bed orga-
and/or lake by motor pumps is pumped nic micro pollutants and chlorine. The
in the first chemical conditioning and system is always equipped with units for
mixing compartment, then by gravity storing and dosing chemicals, automa-
passes in the second flocculation com- tic filters washing and UV system for
partment and the following compart- removing bacteria contamination. After
ment with lamella settling. Raw water, UV treatment will be available water
coming from wells and/or lakes, having complying with the parameter set by
low turbidity or with most of suspended WHO.